Philips Respironics Trilogy 202 - Refurbished
Whether at home or in alternative care sites, the Trilogy 202 portable volume and pressure support ventilator with BiPAP technology is made for adult and pediatric use. Offers Two Circuit Options Interchangeable active and passive exhalation porting blocks give clinicians the flexibility to choose the best available circuit and interface for patients. Its internal PEEP, combined with a single limb circuit, creates an uncomplicated application. Simple Ventilation. Sophisticated Technology. Trilogy makes invasive and noninvasive home ventilation less complicated with a simplified user interface and Respironics' proven BiPAP technology for greater versatility. Its lightweight design and internal and detachable batteries make portability easier for patients on the go. Simplicity Light, versatile, and easy to use, Trilogy202 offers clinicians and patients one of life's greatest qualities - simplicity. Portability Trilogy 202 has been designed with portability in mind. • Weighs 5 kg (11 lb.) • Includes 3-hour internal and 3-hour detachable batteries • Ability to connect to an external lead acid battery DirectView Ventilation Management Software Trilogy 202 provides ventilation data and prescription management through the use of an SD memory card.
- Temperature: 5°C – 40°C
- Relative humidity: 15% – 95%
- Atmospheric pressure: 110 kPa to 60 kPa
- Weight: 11 lbs, 5 kgs
- Size: 6.6"L x 11.2"W x 9.3"H (16.68 cm L x 28.45 cm W x 23.52 cm H)
- Circuit types: Active with PAP, passive
- Ventilation types: Volume control, pressure control, bilevel
- Volume modes: AC, SIMV (w/PS), CV
- Pressure modes: CPAP, S, S/T, T, PC-SIMV (w/PS)
- IPAP: 4 – 50 cm H20
- EPAP: 0 – 25 cm H20 for active circuits; 4 – 25 cm H20 for passive circuits
- CPAP: 4 – 20 cm H20 for passive circuits
- PEEP: 0 – 25 cm H20 for active circuits; 4 – 25 cm H20 for passive circuits
- Pressure support differential: 0 – 30 cm H20
- Tidal volume: 50 – 2000 ml
- Breath rate: 0 – 60 for AC mode, 1 – 60 for all other modes
- Inspiratory time: 0.3 – 5.0 secs
- Rise time: 1 – 6
- Ramp start pressure: 0 – 25 cm H20 for active circuits; 4 – 25 cm H20 for passive circuits; 4 – 19 cm H20 in CPAP mode
- Ramp length: Off, 5 – 45 minutes
- Flex: Off, 1 – 3
- Flow trigger sensitivity: 1 – 9 l/min
- Flow cycle: 10% – 90%
- Apnea rate: 4 – 60 BPM
- Tidal volume: 0 – 2000 ml
- Minute ventilation: 0 – 99 l/min
- Leak rate: 0 – 200 l/min
- Respiratory rate: 0 – 80 BPM
- Peak inspiratory flow: 0 – 200 l/min
- Peak inspiratory pressure: 0 – 99 cm H20
- Mean airway pressure: 0 – 99 cm H20
- Percentage patient triggered breaths: 0 – 100%
- I:E ratio: 9.9:1 to 1:9.9
- Circuit disconnect: Off, 10 – 60 secs
- Apnea: Off, 10 – 60 secs
- High tidal volume: Off, 50 – 2000 ml
- Low tidal volume: Off, 50 – 2000 ml
- High minute ventilation: Off, .1 – 99 l/min
- Low minute ventilation: Off, .1 – 99 l/min
- High respiratory rate: Off, 4 – 80 BPM
- Low respiratory rate: Off, 4 – 80 BPM
Options
- Detachable back-up battery: Offering up to 3 hours additional operating time
- Hospital roll stand: Provides convenient accessory basket and humidifier mount
- DirectView: 1 GB SD card data storage integrated into the ventilator software