Respironics Trilogy 200 Ventilator
- Brand
- Respironics
- SKU:
- TD Trilogy 200 -reb
- Condition:
- Refurbished
- Availability:
- (866) 490-1609
- Weight:
- 18.00 LBS
- Shipping:
- Calculated at Checkout
For Every Breath He Takes Using a new single limb circuit and proximal flow sensor, Trilogy200 offers improved triggering and leak compensation that allows for the more sensitive delivery of therapy. This added sensitivity decreases work of breathing, resulting in greater comfort, better ventilation, and improved patient/ventilator synchrony. Sensitive To Your Patient's Needs Trilogy200's advanced flow triggering is ideal for patients who require enhanced inspiratory triggering and leak compensation. Offers Three Circuit Options Trilogy200's new universal porting block gives you the flexibility to choose from three different circuit configurations and provide the best available option for the patient. Portability Trilogy200 has been designed with portability in mind. • Weighs 5 kg (11 lb.) • Includes 3-hour internal and 3-hour detachable batteries • Ability to connect to an external lead acid battery DirectView Ventilation Management Software Trilogy200 provides ventilation data and prescription management through the use of an SD memory card.
- Temperature: 5°C – 40°C
- Relative humidity: 15% – 95%
- Atmospheric pressure: 110 kPa to 60 kPa
- Weight: 11 lbs, 5 kgs
- Size: 6.6 x 11.2 x 9.5", 16.68 x 28.45 x 23.52cm
- Circuit types: Active with PAP, passive, active with flow
- Ventilation types: Volume control, pressure control, bilevel
- Volume modes: AC, SIMV (w/PS), CV
- Pressure modes: CPAP, S, S/T, T, PC-SIMV (w/PS)
- IPAP: 4 – 50 cm H20
- EPAP: 0 – 25 cm H20 for active circuits; 4 – 25 cm H20 for passive circuits
- CPAP: 4 – 20 cm H20 for passive circuits
- PEEP: 0 – 25 cm H20 for active circuits; 4 – 25 cm H20 for passive circuits
- Pressure support differential: 0 – 30 cm H20
- Tidal volume: 50 – 2000 ml
- Breath rate: 0 – 60 for AC mode, 1 – 60 for all other modes
- Inspiratory time: 0.3 – 5.0 secs
- Rise time: 1 – 6 (The range of values corresponds to tenths of a second. For example, a setting of 4 indicates a rise time of 0.4 seconds.)
- Ramp start pressure: 0 – 25 cm H20 for active circuits; 4 – 25 cm H20 for passive circuits; 4 – 19 cm H20 in CPAP mode
- Ramp length: Off, 5 – 45 minutes
- Flex: Off, 1 – 3
- Flow trigger sensitivity: 1 – 9 l/min
- Flow cycle: 10% – 90%
- Apnea rate: 4 – 60 BPM
- Tidal volume: 0 – 2000 ml
- Minute ventilation: 0 – 99 l/min
- Leak rate: 0 – 200 l/min
- Respiratory rate: 0 – 80 BPM
- Peak inspiratory flow: 0 – 200 l/min
- Peak inspiratory pressure: 0 – 99 cm H20
- Mean airway pressure: 0 – 99 cm H20
- Percentage patient triggered breaths: 0 – 100%
- I:E ratio: 9.9–1:1–9.9
- Circuit disconnect: Off, 5 – 60 secs
- Apnea: Off, 10 – 60 secs
- High tidal volume: Off, 50 – 2000 ml
- Low tidal volume: Off, 40 – 2000 ml
- High minute ventilation: Off, 0.1 – 99 l/min
- Low minute ventilation: Off, 0.1 – 99 l/min
- High respiratory rate: Off, 4 – 80 BPM
- Low respiratory rate: Off, 4 – 80 BPM