Drager Savina Ventilator
Call
- Brand
- Draeger
- SKU:
- TD Savina REB
- Condition:
- Refurbished
- Availability:
- (866) 490-1609
- Weight:
- 0.00 LBS
The dependable Dräger Savina can help you face clinically challenging environments. It is easy to use and combines excellent ventilation performance, quality and versatility.
- Helps minimize risk to the patient
- Adapts to altering needs with ease
- Can support weaning
- Promotes long-term ventilation and recovery
Ventilation performance that is excellent and flexible
- With its open breathing system, the Savina enables spontaneous breathing at any time and any pressure level in all ventilation modes during ventilation cycles
- Features an internal turbine that removes the need for air cylinders or an external compressor
- Navigate power failures and support mobility with an internal battery
- Multiple ventilation modes accommodate various acuity levels and patient populations
High quality; includes safety concept
- Precise, endurable O2 dosage enabled by nine rubies
- Independent, unseen “bodyguards” for improving safety for the patient, and backup twin sensors for airway pressure, FiO2 and minute volume
Design promotes easy use
- Access to key settings for ventilation
- Minimized training time via an intuitive operating concept
- Color screen is bright and high res for high visibility, from up close and a long range
- Attractive in most clinical environments
TECHNICAL SPECIFICATIONS
- Ventilation Mode: PPV (CMV), IPPVAssist (CMVAssist), SIMV, SIMVASB (SIMV/PS) CPAP, CPAPASB (CPAP/PS), BIPAP* (PCV+) (optional) BIPAP* ASB (PCV+/PS) (optional)
- Enhancements:Patient type: Adult, pediatric
- NIV – Non Invasive Ventilation with optimized alarm system and automatic leakage compensation (optional)
- AutoFlow®– Automatic adaptation of the inspiratory flow in volume orientated ventilation modes (optional).
- LPO - Low Pressure Oxygen. Independent oxygen supply, e.g. with an O2 concentrator (optional)
- Graphic screen - Advanced ventilation monitoring (optional)
- Nurse call - Connection for transmitting alarm signals to a central alarm system (optional)
- Ventilation frequency: 2 to 80 bpm
- Tidal volume: 0.05 to 2.0 L, BTPS**)
- Inspiratory flow: 0 to180 L/min
- Inspiratory pressure: 0 to 99 mbar***) (cmH2O)
- PEEP/interm. PEEP: 0 to 35 mbar (cmH2O)
- Pressure support/ASB: 0 to 35 mbar (cmH2O) (relative to PEEP)
- Flow acceleration: 5 to 200 mbar/s (cmH2O/s)
- O2-concentration: 21 to100 Vol. %
- Trigger sensitivity: 1 to15 L/min
- Measured value display
- Airway pressure measurements: Peak pressure, plateau pressure, mean airway pressure, PEEP 0 -100 mbar (cmH2O)
- Minute volume (MV): Total MV, spontaneous MV 0 to 99 L/min, BTPS
- Tidal volume VT: Inspiratory VT, expiratory VT 0 to 3999 mL, BTPS
- Breathing frequency: Total and spontaneous breathing frequency, 0-150 bpm
- Inspiratory O2-concentration: 21 to100 Vol. %
- Breathing gas temperature: 18 to 48 °C (sensor optional)
- Curve displays: Airway pressure / time, flow / time
- Ventilation ratio (I:E): 150:1 to 1:150
- Alarms
- Airway pressures: High / low
- Expiratory minute volume: High / low
- Tidal volume: High / low
- Apnoea-alarm time: 15 to 60 sec
- Spontaneous breathing frequency: High
- Inspiratory O2-concentration: High / low
- Inspiratory breathing gas temperature: High
- Performance data
- Maximum flow for pressure assist/spontaneous breathing: 180 L/min
- Valve response time T0…90: ≤ 5 ms
- Control principle: Time-cycled, volume-constant, pressure-controlled
- Safety valve opening pressure: 100 mbar (cmH2O)
- Emergency valve: Automatically enables spontaneous breathing with filtered ambient air if air and O2 supply should fail
- Automatic gas switch-over function if O2 supply fails
- Output for pneumatic medicament nebuliser: Synchronized with inspiration
- Operating data
- Main power connection 100 V to 240 V, 50/60 Hz AC, 10 to 36 V DC
- Typical power consumption 100 W
- Internal battery Approx. 60 min (optional extension up to 7 h)
- Digital machine outputs
- Digital output and input via an RS 232 C interface, Dräger Medibus standard
- Gas supply
- Air: Turbine technology
- O2 gas supply: 3 bar (39 psi) to 10 % up to 6 bar (87 psi)
- Dimensions and weights
- Dimensions (without trolley): W x H x D 380 x 383 x 358 mm (15.0 x 156.1 x 14.1 inches)
- Weight (basic device): Approx. 24 kg (53 lbs.)
- Diagonal screen size: 6.1” TFT color screen
90 Days